<LOGO>
FM Transmitter Measurement Report
Created: 2026-08-28 21-00-47
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 50 dBuV SANDELS
Pilot RDS Phase Difference
4.9 kHz 5.2 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 71 kHz 15146 22,0388
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,2 dBr 5,42 dBr 6,5 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7, 103.8 MHz -
FM Scope Max at: 71 kHz MIN: 12 kHz % above 76 kHz: 22,0388 Acquired: 2026.08.28 20.59.44 Total samples: 15146 Equivalent time: 0:12:37 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 6,5 dBr MIN: 3,2 dBr AVE: 5,42 dBr % above 12,2 dBr: 0,0 Last value: 6,2 dBr (2026.08.28 20.59.43) 20.46 20.48 20.50 20.52 20.54 20.56 20.58 0 2 4 6 Pm [dBr]